Vp50 series pneumatic proportional valve, used in environmental
protection, biological industry, agriculture, mining, tr
Working principle
Proportional pressure control valves and direct-acting plungers are
in the suction process, at this time the intake valve spring is
compressed, the valve plate moves downward, so the intake valve
opens and inhales gas. When the piston travels back, that is, when
it moves upward from the bottom dead center, the suction valve
begins to close, that is, the valve plate moves upward under the
action of its spring force to the close position of the valve
seat.When the output pressure of the proportional pressure control
valve is higher or the diameter is larger, the pressure regulating
spring is used to directly adjust the pressure, then the spring
stiffness is inevitably too large, and the output pressure
fluctuates greatly when the flow rate changes, and the structural
size of the valve will also increase. In order to overcome these
shortcomings, pilot operated pressure reducing valves can be used.
The working principle of the pilot type pressure reducing valve is
basically the same as that of the direct acting type. The pressure
regulating gas used in the pilot pressure reducing valve is
supplied by a small direct acting pressure reducing valve. If the
small direct-acting pressure reducing valve is installed inside the
valve body, it is called the internal pilot pressure reducing
valve; If the small direct acting pressure reducing valve is
installed outside the main body, it is called an external pilot
pressure reducing valve. Compared with the direct-acting pressure
reducing valve, the valve has added a nozzle baffle amplifier link
composed of a nozzle 4, a baffle fixed orifice 9 and an air chamber
B.When the distance between the nozzle and the baffle changes
slightly, the pressure in chamber B will change significantly,
resulting in a large displacement of the diaphragm 10, to control
the up and down movement of the valve core 6, so that the intake
valve port 8 is opened or closed, and the sensitivity of the
control of the valve core is improved, that is, the pressure
regulation accuracy is improved.
Technical parameter |
Maximum working pressure | 12.0 bar |
Operating temperature | 0 to 50 ℃ |
Electrical connection | M12*15 stitches |
Class of protection | IP65 |
Spool sealing technology | Hard seal spool and sleeve |
Flow rate | 1400I/min |
Control accuracy | 0.1% |
Total error | <1% |
Thermoplastic elastomer | Nitrile butadiene rubber |
Main body | Aluminum; High pressure die casting |
Control signal | 0-10V |
Output pressure | 0-6bar |